NET101 User’s Manual -24-
Appendix A: Methods to Update NET101 Firmware
Method 3: Using IE Browser
This method uses IE to update the latest firmware. Open IE, then type in the
account, password and NET101 IP address to be updated in the following format,
ftp://<username>:<password>@<NET101 IP address>.
Once logged in, the current firmware and version will be displayed. Copy the
latest firmware to here to complete the updating process.
There are two method to log in:
(a) ftp://admin:p[email protected]
Enter the password that was set earlier using Netility. Otherwise, enter
NET101’s default value:
Username: admin
Password: <blank>
(example:
ftp://admin:@192.168.50.179)
(b) ftp://192.168.50.179/
The follow error message will show, when the above is entered. Ignore it and
select “Enter Identity” at the top left corner of file menu. Then enter “admin”
as the User Name and <blank> Password to re-enter.
Once the connection has been established, the following window will be
Vista de página 25